Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Clin Chem Lab Med ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38456798

RESUMO

OBJECTIVES: Early diagnosis of inborn errors of metabolism (IEM) is crucial to ensure early detection of conditions which are treatable. This study reports on targeted metabolomic procedures for the diagnosis of IEM of amino acids, acylcarnitines, creatine/guanidinoacetate, purines/pyrimidines and oligosaccharides, and describes its validation through external quality assessment schemes (EQA). METHODS: Analysis was performed on a Waters ACQUITY UPLC H-class system coupled to a Waters Xevo triple-quadrupole (TQD) mass spectrometer, operating in both positive and negative electrospray ionization mode. Chromatographic separation was performed on a CORTECS C18 column (2.1 × 150, 1.6 µm). Data were collected by multiple reaction monitoring. RESULTS: The internal and EQA results were generally adequate, with a few exceptions. We calculated the relative measurement error (RME) and only a few metabolites displayed a RME higher than 30 % (asparagine and some acylcarnitine species). For oligosaccharides, semi-quantitative analysis of an educational panel clearly identified the 8 different diseases included. CONCLUSIONS: Overall, we have validated our analytical system through an external quality control assessment. This validation will contribute to harmonization between laboratories, thus improving identification and management of patients with IEM.

2.
J Lipid Res ; 65(3): 100516, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38320654

RESUMO

The gold-standard diagnostic test for peroxisomal disorders (PDs) is plasma concentration analysis of very long-chain fatty acids (VLCFAs). However, this method's time-consuming nature and limitations in cases which present normal VLCFA levels necessitates alternative approaches. The analysis of C26:0-lysophosphatydylcholine (C26:0-LPC) in dried blood spot samples by tandem-mass spectrometry (MS/MS) has successfully been implemented in certain newborn screening programs to diagnose X-linked adrenoleukodystrophy (ALD). However, the diagnostic potential of very long-chain LPCs concentrations in plasma remains poorly understood. This study sought to evaluate the diagnostic performance of C26:0-LPC and other very long-chain LPCs, comparing them to VLCFA analysis in plasma. The study, which included 330 individuals affected by a peroxisomal ß-oxidation deficiency and 407 control individuals, revealed that C26:0- and C24:0-LPC concentrations demonstrated the highest diagnostic accuracy (98.8% and 98.4%, respectively), outperforming VLCFA when C26:0/C22:0 and C24:0/C22:0 ratios were combined (98.1%). Combining C24:0- and C26:0-LPC gave the highest sensitivity (99.7%), with ALD females exhibiting notably higher sensitivity compared with the VLCFA ratio combination (98.7% vs. 93.5%, respectively). In contrast, C22:0-LPC exhibited suboptimal performance, primarily due to its low sensitivity (75%), but we identified a potential use to help distinguish between ALD and Zellweger spectrum disorders. In summary, MS/MS analysis of plasma C24:0- and C26:0-LPC concentrations represents a rapid and straightforward approach to diagnose PDs, demonstrating superior diagnostic accuracy, particularly in ALD females, compared with conventional VLCFA biomarkers. We strongly recommend integrating very-long chain LPC plasma analysis in the diagnostic evaluation of individuals suspected of having a PD.


Assuntos
Adrenoleucodistrofia , Lisofosfatidilcolinas , Recém-Nascido , Feminino , Humanos , Espectrometria de Massas em Tandem , Adrenoleucodistrofia/diagnóstico , Triagem Neonatal/métodos , Biomarcadores , Ácidos Graxos não Esterificados , Ácidos Graxos
3.
Clin Chem Lab Med ; 62(3): 493-505, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-37794778

RESUMO

OBJECTIVES: Acylcarnitine and amino acid analyses of dried blood spot (DBS) samples using tandem mass spectrometry in newborn screening (NBS) programmes can generate false positive (FP) results. Therefore, implementation of second-tier tests (2TTs) using DBS samples has become increasingly important to avoid FPs. The most widely used 2TT metabolites include methylmalonic acid, 3-hydroxypropionic acid, methylcitric acid, and homocysteine. METHODS: We simultaneously measured 46 underivatised metabolites, including organic acids, acylglycine and acylcarnitine isomers, homocysteine, and orotic acid, in DBS samples using tandem mass spectrometry. To validate this method, we analysed samples from 147 healthy newborns, 160 patients with genetic disorders diagnosed via NBS, 20 patients with acquired vitamin B12 deficiency, 10 newborns receiving antibiotic treatment, and nine external quality control samples. RESULTS: The validation study revealed that 31 metabolites showed good analytical performance. Furthermore, this method detected key metabolites for all diseases associated with increased levels of the following acylcarnitines: C3, C4, C5, C4DC/C5OH, and C5DC. The sensitivity of this method to detect all diseases was 100 %, and the specificity was 74-99 %, except for glutaric aciduria type 1. This method can also be used to diagnose mitochondrial fatty acid ß-oxidation disorders (FAODs) and urea cycle defects (UCDs). CONCLUSIONS: We have described a 2TT panel of 31 metabolites in DBS samples based on an easy and rapid method without derivatisation. Its implementation allowed us to distinguish between different organic acidurias, some FAODs, and UCDs. This new strategy has increased the efficiency of our NBS programme by reducing FP and false negative results, second sample requests, and the time required for diagnosis.


Assuntos
Erros Inatos do Metabolismo dos Aminoácidos , Encefalopatias Metabólicas , Carnitina/análogos & derivados , Glutaril-CoA Desidrogenase/deficiência , Triagem Neonatal , Espectrometria de Massas em Tandem , Humanos , Recém-Nascido , Espectrometria de Massas em Tandem/métodos , Triagem Neonatal/métodos , Espanha , Cromatografia Líquida/métodos , Homocisteína , Teste em Amostras de Sangue Seco/métodos
4.
J Clin Med ; 12(23)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38068509

RESUMO

Phenylketonuria (PKU) is the most frequent of the congenital errors of amino acid (AA) metabolism worldwide. It leads to the accumulation of the essential AA phenylalanine (Phe) and it is associated with severe neurological defects. The early diagnosis and treatment of this rare disease, achieved through newborn screening and low-Phe diet, has profoundly changed its clinical spectrum, resulting in normal cognitive development. We face the first generation of PKU patients perinatally diagnosed and treated who have reached adulthood, whose special needs must be addressed, including feeding through enteral nutrition (EN). However, recommendations regarding EN in PKU constitute a gap in the literature. Although protein substitutes for patients with PKU are offered in multiple forms (Phe-free L-amino acid or casein glycomacropeptide supplements), none of these commercial formulas ensures the whole provision of daily total energy and protein requirements, including a safe amount of Phe. Consequently, the combination of different products becomes necessary when artificial nutrition via tube feeding is required. Importantly, the composition of these specific formulas may result in physicochemical interactions when they are mixed with standard EN products, leading to enteral feeding tubes clogging, and also gastrointestinal concerns due to hyperosmolality. Herein, we present the first reported case of EN use in an adult patient with PKU, where the separate administration of protein substitutes and the other EN products avoided physicochemical interactions.

5.
J Clin Med ; 12(19)2023 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-37835050

RESUMO

Lysinuric protein intolerance (LPI) is a rare inborn error of metabolism (IEM), classified as an inherited aminoaciduria, caused by mutations in the SLC7A7 gene, leading to a defective cationic amino acid transport. The metabolic adaptations to the demands of pregnancy and delivery cause significant physiological stress, so those patients affected by IEM are at greater risk of decompensation. A 28-year-old woman with LPI had experienced 3 early miscarriages. While pregnancy was finally achieved, diverse nutritional and medical challenges emerged (food aversion, intrauterine growth restriction, bleeding risk, and preeclampsia suspicion), which put both the mother and the fetus at risk. Moreover, the patient requested a natural childbirth (epidural-free, delayed cord clamping). Although the existence of multiple safety concerns rejected this approach at first, the application of novel strategies made a successful delivery possible. This case reinforces that the woman's wish for a non-medicated, low-intervention natural birth should not be automatically discouraged because of an underlying complex metabolic condition. Achieving a successful pregnancy is conceivable thanks to the cooperation of interdisciplinary teams, but it is still important to consider the risks beforehand in order to be prepared for possible additional complications.

6.
J Inherit Metab Dis ; 46(6): 1029-1042, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37718653

RESUMO

The determination of the functional impact of variants of uncertain significance (VUS) is one of the major bottlenecks in the diagnostic workflow of inherited genetic diseases. To face this problem, we set up a CRISPR/Cas9-based strategy for knock-in cellular model generation, focusing on inherited metabolic disorders (IMDs). We selected variants in seven IMD-associated genes, including seven reported disease-causing variants and four benign/likely benign variants. Overall, 11 knock-in cell models were generated via homology-directed repair in HAP1 haploid cells using CRISPR/Cas9. The functional impact of the variants was determined by analyzing the characteristic biochemical alterations of each disorder. Functional studies performed in knock-in cell models showed that our approach accurately distinguished the functional effect of pathogenic from non-pathogenic variants in a reliable manner in a wide range of IMDs. Our study provides a generic approach to assess the functional impact of genetic variants to improve IMD diagnosis and this tool could emerge as a promising alternative to invasive tests, such as muscular or skin biopsies. Although the study has been performed only in IMDs, this strategy is generic and could be applied to other genetic disorders.


Assuntos
Sistemas CRISPR-Cas , Doenças Metabólicas , Humanos , Sistemas CRISPR-Cas/genética , Virulência , Genômica , Doenças Metabólicas/genética
7.
Int J Mol Sci ; 24(15)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37569695

RESUMO

CCDC186 protein is involved in the maturation of dense-core vesicles (DCVs) in the trans-Golgi network in neurons and endocrine cells. Mutations in genes involved in DCV regulation, other than CCDC186, have been described in patients with neurodevelopmental disorders. To date, only one patient, within a large sequencing study of 1000 cases, and a single case report with variants in CCDC186, had previously been described. However, no functional studies in any of these two cases had been performed. We identified three patients from two gypsy families, unrelated to each other, with mutations in the CCDC186 gene. Clinically, all patients presented with seizures, frontotemporal atrophy, hypomyelination, recurrent infections, and endocrine disturbances such as severe non-ketotic hypoglycemia. Low levels of cortisol, insulin, or growth hormone could only be verified in one patient. All of them had a neonatal onset and died between 7 months and 4 years of age. Whole exome sequencing identified a homozygous variant in the CCDC186 gene (c.2215C>T, p.Arg739Ter) in the index patients of both families. Protein expression studies demonstrated that CCDC186 was almost undetectable in fibroblasts and muscle tissue. These observations correlated with the transcriptomic analysis performed in fibroblasts in one of the patients, which showed a significant reduction of CCDC186 mRNA levels. Our study provides functional evidence that mutations in this gene have a pathogenic effect on the protein and reinforces CCDC186 as a new disease-associated gene. In addition, mutations in CCDC186 could explain the combined endocrine and neurologic alterations detected in our patients.


Assuntos
Doenças do Sistema Endócrino , Transtornos do Neurodesenvolvimento , Recém-Nascido , Humanos , Sistema Nervoso Central , Transtornos do Neurodesenvolvimento/genética , Mutação , Rede trans-Golgi
9.
Int J Mol Sci ; 23(20)2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-36293220

RESUMO

Peroxisomal biogenesis disorders (PBDs) are a heterogeneous group of genetic diseases. Multiple peroxisomal pathways are impaired, and very long chain fatty acids (VLCFA) are the first line biomarkers for the diagnosis. The clinical presentation of PBDs may range from severe, lethal multisystemic disorders to milder, late-onset disease. The vast majority of PBDs belong to Zellweger Spectrum Disordes (ZSDs) and represents a continuum of overlapping clinical symptoms, with Zellweger syndrome being the most severe and Heimler syndrome the less severe disease. Mild clinical conditions frequently present normal or slight biochemical alterations, making the diagnosis of these patients challenging. In the present study we used a combined WES and RNA-seq strategy to diagnose a patient presenting with retinal dystrophy as the main clinical symptom. Results showed the patient was compound heterozygous for mutations in PEX1. VLCFA were normal, but retrospective analysis of lysosphosphatidylcholines (LPC) containing C22:0-C26:0 species was altered. This simple test could avoid the diagnostic odyssey of patients with mild phenotype, such as the individual described here, who was diagnosed very late in adult life. We provide functional data in cell line models that may explain the mild phenotype of the patient by demonstrating the hypomorphic nature of a deep intronic variant altering PEX1 mRNA processing.


Assuntos
Surdez , Perda Auditiva Neurossensorial , Síndrome de Zellweger , Humanos , ATPases Associadas a Diversas Atividades Celulares/metabolismo , RNA-Seq , Estudos Retrospectivos , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Síndrome de Zellweger/diagnóstico , Síndrome de Zellweger/genética , Perda Auditiva Neurossensorial/genética , Biomarcadores , RNA Mensageiro , Ácidos Graxos
10.
Biochem Med (Zagreb) ; 32(3): 030901, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35966259

RESUMO

Introduction: To ensure the quality of the new-born screening (NBS), our laboratory reviewed the analytical procedure to detect subjective steps that may represent a risk to the patient. Two subjective activities were identified in the extra-analytical phases: the classification of dried blood spots (DBS) according to their quality and the assignment of haemoglobin patterns. To keep these activities under control, inter-rater studies were implemented. This study aimed to evaluate the inter-rater reliability and the effectiveness of the measures taken to improve the agreement between observers, to assure NBS results' quality. Materials and methods: Dried blood spots specimens were used for the inter-rater studies. Ten studies were performed to assess DBS quality classification, and four to assess the assignment of haemoglobin patterns. Krippendorff's alpha test was used to estimate inter-rater reliability. Causes were investigated when alpha values were below 0.80. Results: For both activities, the reliability obtained in the first studies was inadequate. After investigation, we detected that the criterion to classify a DBS as scant was not consolidated, and also a lack of consensus on whether or not to report Bart's haemoglobin depending on its percentage. Alpha estimates became higher once the training was reinforced and a consensus about the appropriate criteria to be applied was reached. Conclusion: Inter-rater reliability assessment helped us to ensure the quality of subjective activities that could add variability to NBS results. Furthermore, the evolution of the alpha value over time allowed us to verify the effectiveness of the measures adopted.


Assuntos
Hemoglobinas , Humanos , Reprodutibilidade dos Testes
11.
Antioxidants (Basel) ; 11(3)2022 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-35326178

RESUMO

The biochemical measurement of the CoQ status in different tissues can be performed using HPLC with electrochemical detection (ED). Because the production of the electrochemical cells used with the Coulochem series detectors was discontinued, we aimed to standardize a new HPLC-ED method with new equipment. We report all technical aspects, troubleshooting and its performance in different biological samples, including plasma, skeletal muscle homogenates, urine and cultured skin fibroblasts. Analytical variables (intra- and inter-assay precision, linearity, analytical measurement range, limit of quantification, limit of detection and accuracy) were validated in calibrators and plasma samples and displayed adequate results. The comparison of the results of a new ERNDIM external quality control (EQC) scheme for the plasma CoQ determination between HPLC-ED (Lab 1) and LC-MS/MS (Lab 2) methods shows that the results of the latter were slightly higher in most cases, although a good consistency was generally observed. In conclusion, the new method reported here showed a good analytical performance. The global quality of the EQC scheme results among different participants can be improved with the contribution of more laboratories.

12.
Int J Neonatal Screen ; 7(4)2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34698070

RESUMO

Purine nucleoside phosphorylase (PNP) deficiency is a rare inherited disorder, resulting in severe combined immunodeficiency. To date, PNP deficiency has been detected in newborn screening only through the use of liquid chromatography tandem mass spectrometry. We report the first case in which PNP deficiency was detected by TREC analysis.

13.
Int J Neonatal Screen ; 7(3)2021 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-34294672

RESUMO

Newborn screening (NBS) for severe combined immunodeficiency (SCID) started in Catalonia in January-2017, being the first Spanish and European region to universally include this testing. In Spain, a pilot study with 5000 samples was carried out in Seville in 2014; also, a research project with about 35,000 newborns will be carried out in 2021-2022 in the NBS laboratory of Eastern Andalusia. At present, the inclusion of SCID is being evaluated in Spain. The results obtained in the first three and a half years of experience in Catalonia are presented here. All babies born between January-2017 and June-2020 were screened through TREC-quantification in DBS with the Enlite Neonatal TREC-kit from PerkinElmer. A total of 222,857 newborns were screened, of which 48 tested positive. During the study period, three patients were diagnosed with SCID: an incidence of 1 in 74,187 newborns; 17 patients had clinically significant T-cell lymphopenia (non-SCID) with an incidence of 1 in 13,109 newborns who also benefited from the NBS program. The results obtained provide further evidence of the benefits of early diagnosis and curative treatment to justify the inclusion of this disease in NBS programs. A national NBS program is needed, also to define the exact SCID incidence in Spain.

14.
Clin Biochem ; 97: 78-81, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34329621

RESUMO

In the field of laboratory medicine, proficiency testing is a vehicle used to improve the reliability of reported results. When proficiency tests are unavailable for a given analyte, an alternative approach is required to ensure adherence to the International Organization for Standardization (ISO) 15189:2012 standard. In this study, we report the results of a split-sample testing program performed as an alternative to a formal PT. This testing method was based on recommendations provided in the Clinical and Laboratory Standards Institute (CLSI) QMS24 guideline. Two different laboratories measured, in duplicate, the heparan sulfate concentration in five samples using ultra-performance liquid chromatography and tandem mass spectrometry. The data analysis to determine the criterion used for the comparability assessment between the two laboratories was based on Appendix E of the QMS24 guideline. Mean interlaboratory differences fell within the maximum allowable differences calculated from the application of the QMS24 guideline, indicating that the results obtained by the two laboratories were comparable across the concentrations tested. Application of the QMS24 split-sample testing procedure allows laboratories to objectively assess test results, thus providing the evidence needed to face an accreditation audit with confidence. However, due to the limitations of statistical analyses in small samples (participants and/or materials), laboratory specialists should assess whether the maximum allowable differences obtained are suitable for the intended use, and make adjustments if necessary.


Assuntos
Laboratórios Clínicos/normas , Ensaio de Proficiência Laboratorial/métodos , Controle de Qualidade , Cromatografia Líquida/normas , Heparitina Sulfato/análise , Heparitina Sulfato/sangue , Humanos , Espectrometria de Massas em Tandem/normas
15.
Orphanet J Rare Dis ; 16(1): 195, 2021 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-33931066

RESUMO

BACKGROUND: Alteration of vitamin B12 metabolism can be genetic or acquired, and can result in anemia, failure to thrive, developmental regression and even irreversible neurologic damage. Therefore, early diagnosis and intervention is critical. Most of the neonatal cases with acquired vitamin B12 deficiency have been detected by clinical symptoms and only few of them trough NBS programs. We aim to assess the usefulness of the second-tier test: methylmalonic acid (MMA), methylcitric acid (MCA) and homocysteine (Hcys) in our newborn screening program and explore the implications on the detection of cobalamin (vitamin B12) related disorders, both genetic and acquired conditions. METHODS: A screening strategy using the usual primary markers followed by the analysis of MMA, MCA and Hcys as second tier-test in the first dried blood spot (DBS) was developed and evaluated. RESULTS: During the period 2015-2018 a total of 258,637 newborns were screened resulting in 130 newborns with acquired vitamin B12 deficiency (incidence 1:1989), 19 with genetic disorders (incidence 1:13,613) and 13 were false positive. No false negatives were notified. Concerning the second-tier test, the percentage of cases with MMA above the cut-off levels, both for genetic and acquired conditions was very similar (58% and 60%, respectively). Interestingly, the percentage of cases with increased levels of Hcys was higher in acquired conditions than in genetic disorders (87% and 47%, respectively). In contrast, MCA was high only in 5% of the acquired conditions versus in 53% of the genetic disorders, and it was always very high in all patients with propionic acidemia. CONCLUSIONS: When screening for methylmalonic acidemia and homocystinuria, differential diagnosis with acquired vitamin B12 deficiency should be done. The results of our strategy support the inclusion of this acquired condition in the NBS programs, as it is easily detectable and allows the adoption of corrective measures to avoid the consequences of its deficiency.


Assuntos
Acidemia Propiônica , Deficiência de Vitamina B 12 , Homocisteína , Humanos , Recém-Nascido , Ácido Metilmalônico , Triagem Neonatal , Vitamina B 12 , Deficiência de Vitamina B 12/diagnóstico , Deficiência de Vitamina B 12/genética , Vitaminas
16.
J Inherit Metab Dis ; 44(4): 961-971, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33861472

RESUMO

Acute intermittent porphyria (AIP) is a rare metabolic disease caused by mutations within the hydroxymethylbilane synthase gene. Previous studies have reported increased levels of plasma total homocysteine (tHcy) in symptomatic AIP patients. In this study, we present long-term data for tHcy and related parameters for an AIP patient cohort (n = 37) in different clinical disease-states. In total, 25 patients (68%) presented with hyperhomocysteinemia (HHcy; tHcy > 15 µmol/L) during the observation period. HHcy was more frequent in AIP patients with recurrent disease receiving heme arginate, than in nonrecurrent (median tHcy: 21.6 µmol/L; range: 10-129 vs median tHcy: 14.5 µmol/L; range 6-77). Long-term serial analyses showed a high within-person tHcy variation, especially among the recurrent patients (coefficient of variation: 16.4%-78.8%). HHcy was frequently associated with low blood concentrations of pyridoxal-5'-phosphate and folate, while cobalamin concentration and the allele distribution of the methylene-tetrahydrofolate-reductase gene were normal. Strikingly, 6 out of the 9 recurrent patients who were later included in a regime of givosiran, a small-interfering RNA that effectively reduced recurrent attacks, showed further increased tHcy (median tHcy in 9 patients: 105 µmol/L; range 16-212). Screening of amino acids in plasma by liquid-chromatography showed co-increased levels of methionine (median 71 µmol/L; range 23-616; normal <40), suggestive of acquired deficiency of cystathionine-ß-synthase. The kynunerine/tryptophan ratio in plasma was, however, normal, indicating a regular metabolism of tryptophan by heme-dependent enzymes. In conclusion, even if HHcy was observed in AIP patients receiving heme arginate, givosiran induced an aggravation of the dysregulation, causing a co-increase of tHcy and methionine resembling classic homocystinuria.


Assuntos
Acetilgalactosamina/análogos & derivados , Arginina/deficiência , Heme/deficiência , Hiper-Homocisteinemia/etiologia , Porfiria Aguda Intermitente/tratamento farmacológico , Pirrolidinas/uso terapêutico , Acetilgalactosamina/efeitos adversos , Acetilgalactosamina/uso terapêutico , Adulto , Arginina/uso terapêutico , Cistationina beta-Sintase/genética , Feminino , Ácido Fólico/sangue , Heme/uso terapêutico , Homeostase , Homocisteína/metabolismo , Homocistinúria/complicações , Humanos , Hidroximetilbilano Sintase/sangue , Hidroximetilbilano Sintase/genética , Masculino , Metionina/sangue , Pessoa de Meia-Idade , Porfiria Aguda Intermitente/sangue , Porfiria Aguda Intermitente/complicações , Porfiria Aguda Intermitente/genética , Fosfato de Piridoxal/sangue , Pirrolidinas/efeitos adversos , Adulto Jovem
17.
Rev Esp Salud Publica ; 942020 Dec 16.
Artigo em Espanhol | MEDLINE | ID: mdl-33323919

RESUMO

The Neonatal Screening Program in Catalonia from its inception fifty years ago until today, has enabled the early diagnosis and treatment of more than 2,000 newborns. In the last decade, the Program has undergone various extensions regarding its panel of diseases and has improved its evaluation with the inclusion of quality indicators in all its stages. One of the pending subjects of the screening program has been the improvement of the quality indexes related to the sample's arrival time to the laboratory after their extraction. The extension of the territory, the dispersion of numerous maternal centers, as well as the diversity and heterogeneity of the sample transport systems, have been an obstacle to quality compliance of these indexes. With the aim of reducing the period of samples arrival to the laboratory and continue to move towards meeting the standards established by the Ministry of Health, in 2020 a unified sample transport system has been implemented for the entire Catalan territory. The times obtained during the first months with the new system, have shown a notable improvement in the results, achieving a reduction of 50% of the days between the extraction of the sample and its arrival at the laboratory.


El Programa de Cribado Neonatal (PCN) de Cataluña ha permitido el diagnóstico y tratamiento precoz de más de 2.000 recién nacidos desde su inicio hace cincuenta años hasta la actualidad. En la última década, el PCN ha experimentado diversas ampliaciones en cuanto a su panel de enfermedades y ha mejorado su evaluación con la inclusión de indicadores de calidad en todas sus etapas. Una de las asignaturas pendientes del programa de cribado ha sido la mejora de los indicadores relativos al tiempo de llegada de las muestras al laboratorio desde su extracción. La extensión territorial, la dispersión de los sesenta y seis centros maternales, así como la diversidad y heterogeneidad de los sistemas de transporte de muestras, han supuesto un obstáculo para el cumplimiento de la calidad de este indicador. Con el objetivo de reducir el período de llegada de las muestras al laboratorio y seguir avanzando en el cumplimiento de los estándares establecidos por el Ministerio de Sanidad, en 2020 se ha implementado un sistema de transporte de muestras unificado para todo el territorio catalán. Los tiempos obtenidos durante los primeros meses con el nuevo sistema muestran una mejora notable de los resultados, consiguiendo una reducción del 50% de los días transcurridos desde la extracción de la muestra hasta su llegada al laboratorio.


Assuntos
Triagem Neonatal/organização & administração , Melhoria de Qualidade/organização & administração , Manejo de Espécimes/métodos , Meios de Transporte/métodos , Humanos , Recém-Nascido , Triagem Neonatal/métodos , Melhoria de Qualidade/estatística & dados numéricos , Espanha , Manejo de Espécimes/normas , Manejo de Espécimes/estatística & dados numéricos , Fatores de Tempo , Meios de Transporte/normas , Meios de Transporte/estatística & dados numéricos
18.
Rev Esp Salud Publica ; 942020 Dec 16.
Artigo em Espanhol | MEDLINE | ID: mdl-33323921

RESUMO

Faced with the prospect of a collapsed health system due to the COVID-19 pandemic, the professionals involved in the Neonatal Screening Programme (NSP) of Catalonia had to adapt to this situation in a flexible, forceful and efficient manner. The most important goals were to prevent the risk of infection in the professionals, in families and their newborns, as well as to ensure the same effectiveness for the early detection of the diseases included in our programme. To this end, the laboratory was reorganised by dividing the staff into groups and the spaces were redistributed. It was also necessary to modify several protocols and circuits, especially for the management of early discharges from maternity centres, and for the collection of the necessary second samples (from newborns with inconclusive results or for low quality samples). In general, a 36% reduction in the time of arrival of these second samples at the laboratory was achieved with respect to the previous circuit. In the specific case of cystic fibrosis detection, the implementation of a new strategy meant a 100% reduction in the request for second samples and a 70% reduction in the age of diagnosis of the newborn. After evaluating these changes, it can be concluded that in the face of the pandemic, the NSP of Catalonia showed determined leadership, aligning all its professionals, ensuring the continuity of the activity in the programme and generating new opportunities. The new processes and circuits implemented have been definitively consolidated, improving the efficiency of the programme.


Ante la crisis de un sistema sanitario colapsado debido a la pandemia por la COVID-19, los profesionales implicados en el Programa de Cribado Neonatal (PCN) de Cataluña nos tuvimos que adaptar a dicha situación de forma ágil, contundente y eficiente. Los objetivos prioritarios fueron prevenir el riesgo de contagio tanto en los profesionales sanitarios como en las familias y sus recién nacidos, así como asegurar la misma eficacia para la detección precoz de las enfermedades incluidas en el PCN. Para ello, se reorganizó el laboratorio dividiendo en grupos al personal y se redistribuyeron los espacios. También fue necesario modificar varios protocolos y circuitos, en especial para la gestión de las altas precoces de los centros maternales y para la toma de las segundas muestras necesarias (de recién nacidos que presentaron resultados dudosos o por muestra inválida). En general, se consiguió una reducción del 36% del tiempo de llegada de estas segundas muestras al laboratorio respecto al circuito anterior. Para la detección de la fibrosis quística, la implementación de una nueva estrategia supuso una reducción del 100% en la solicitud de segundas muestras y del 70% en la edad de diagnóstico del recién nacido. Tras la evaluación de estos cambios, se puede concluir que ante la pandemia el PCN de Cataluña mostró un liderazgo decidido, alineando a todos sus profesionales, asegurando la continuidad de la actividad en el programa y generando nuevas oportunidades. Los nuevos procesos y circuitos de trabajo implantados han quedado definitivamente consolidados, mejorando la eficiencia del programa.


Assuntos
COVID-19/epidemiologia , Fibrose Cística/diagnóstico , Triagem Neonatal/métodos , Triagem Neonatal/tendências , Feminino , Humanos , Recém-Nascido , Laboratórios , Liderança , Pandemias , Gravidez , Risco , Espanha/epidemiologia
19.
Rev Esp Salud Publica ; 942020 Dec 16.
Artigo em Espanhol | MEDLINE | ID: mdl-33323922

RESUMO

OBJECTIVE: Newborn screening programmes (NBSP) have experienced a qualitative breakthrough due to the implementation of tandem mass spectrometry. However, the tests used give rise to false positives (FP) generating an excessive request for second samples with the consequent anxiety of the families. In order to avoid this problem several programmes have developed second-tier tests (2TT). METHODS: This article presents our experience in the implementation of 2TT in the NBSP of Catalonia, as well as in other international programmes. RESULTS: From 2004 to the present, 2TT tests have been developed for more than 30 diseases. The use of 2TT helps to decrease the FP rate and increase the positive predictive value (PPV). In the NBSP of Catalonia, the implementation of 2TT for the detection of methylmalonic and propionic acidemias, homocystinurias, maple syrup disease and citrulinaemia, has managed to increase the PPV to 95% and decrease the PF rate to less than 0.01%. In cystic fibrosis, the application of 2TT slightly increases PPV but with a significant decrease in the request for second samples and in the number of cases referred to clinical units. CONCLUSIONS: The introduction of 2TT in the NBSP allows to reduce considerably the FP, decreases the number of requested samples, as well as both anxiety and stress of the families, at the same time that the hospital costs are reduced and the PPV is increased, improving notably the efficiency of the NBSP.


OBJETIVO: Los programas de cribado neonatal (PCN) han experimentado un gran avance cualitativo debido a la implementación de la espectrometría de masas en tándem. Sin embargo, las pruebas utilizadas dan lugar a falsos positivos (FP) generando una excesiva solicitud de segundas muestras con la consiguiente ansiedad de las familias. Con el fin de evitar este problema diversos programas han desarrollado pruebas de segundo nivel (2TT). METODOS: En este artículo se presenta nuestra experiencia en la implementación de 2TT en el PCN de Cataluña, así como en otros programas internacionales. RESULTADOS: Desde el año 2004 hasta la actualidad se han desarrollado pruebas de 2TT para más de 30 enfermedades. La utilización de 2TT ayuda a disminuir la tasa de FP y aumentar el valor predictivo positivo (VPP). En el PCN de Cataluña, la implementación de 2TT para la detección de acidemias metilmalónicas y propiónica, homocistinurias, jarabe de arce y citrulinemia, ha conseguido aumentar el VPP a un 95% y disminuir la tasa de FP a menos del 0,01%. En la fibrosis quística la aplicación de 2TT aumenta ligeramente el VPP pero con disminución significativa de la solicitud de segundas muestras y de los casos referidos a las unidades clínicas. CONCLUSIONES: La introducción de los 2TT en los PCN permite reducir considerablemente los FP, disminuye el número de muestras solicitadas, así como la ansiedad y el estrés de las familias, a la vez que se reducen los costes hospitalarios y se aumenta el VPP, mejorando notablemente la eficiencia de los PCN.


Assuntos
Fibrose Cística/diagnóstico , Erros Inatos do Metabolismo/diagnóstico , Triagem Neonatal/métodos , Imunodeficiência Combinada Severa/diagnóstico , Espectrometria de Massas em Tandem/métodos , Ansiedade/etiologia , Ansiedade/prevenção & controle , Biomarcadores/sangue , Fibrose Cística/sangue , Reações Falso-Positivas , Família/psicologia , Humanos , Recém-Nascido , Cooperação Internacional , Erros Inatos do Metabolismo/sangue , Triagem Neonatal/psicologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Imunodeficiência Combinada Severa/sangue , Espanha , Estresse Psicológico/etiologia , Estresse Psicológico/prevenção & controle
20.
Rev Esp Salud Publica ; 942020 Dec 16.
Artigo em Espanhol | MEDLINE | ID: mdl-33323927

RESUMO

Severe combined immunodeficiency (SCID), the most severe form of T-cell immunodeficiency, can be screened at birth by quantifying T-cell receptor excision circles (TREC) in dried blood spot (DBS) samples. Early detection of this condition speeds up the establishment of appropriate treatment and increases the patient's life expectancy. Newborn screening for SCID started in January 2017 in Catalonia, the first Spanish and European region to universally include this testing. The results obtained in the first three years and a half of experience (January 2017 - June 2020) are shown here, using EnLite Neonatal TREC kit (Perkin Elmer) with 20 copies/µL as TREC detection cutoff. Of 222,857 newborns screened, 48 tested positive: three patients were diagnosed with SCID (incidence 1:74,285); 17 patients had clinically significant T-cell lymphopenia (non-SCID) with an incidence of 1 in 13,109 newborns; twenty two patients were considered false-positive cases because of an initially normal lymphocyte count with normalization of TREC between 3 and 6 months of life; one case had transient lymphopenia due to an initially low lymphocyte count with recovery in the following months; and five patients are still under study. The results obtained provide further evidence of the benefits of including this disease in newborn screening programs. Even longer follow-up could be necessary to define the exact incidence of SCID in Catalonia.


La inmunodeficiencia combinada grave (IDCG) es la forma más grave de inmunodeficiencia primaria, que afecta sobre todo a los linfocitos T, y puede ser detectada al nacer mediante la cuantificación de los círculos de escisión del receptor de linfocitos T (TREC) en una muestra de sangre impregnada en papel (DBS). La detección precoz de esta enfermedad permite establecer de forma temprana un tratamiento adecuado en el paciente, permitiendo así su curación. El cribado neonatal de IDCG comenzó en Cataluña en enero de 2017, siendo la primera región española y europea en incluirla oficial y universalmente en su programa. En el presente trabajo se presentan los resultados obtenidos durante los tres primeros años y medio de experiencia (enero 2017 ­ junio 2020) empleando el kit EnLite Neonatal TREC (Perkin Elmer), con un cutoff de detección de TREC de 20 copias/µL. De 222.857 recién nacidos analizados, cuarenta y ocho fueron detecciones positivas: tres casos de IDCG (incidencia de 1:74.285); diecisiete casos de linfopenia T no IDCG (incidencia de 1:13.109); veintidós casos falsos positivos (recuento de linfocitos inicialmente normal, con normalización de TREC entre los tres y seis meses de vida); un caso con linfopenia transitoria (con un recuento de linfocitos inicialmente bajo, que se normaliza en los meses siguientes); y cinco pacientes se encuentran todavía en estudio. Los resultados obtenidos aportan evidencias de los beneficios que supone incluir esta enfermedad en los programas de cribado neonatal. Podría ser necesario un seguimiento todavía más prolongado para acabar de definir la incidencia exacta de IDCG en Cataluña.


Assuntos
Triagem Neonatal/métodos , Imunodeficiência Combinada Severa/diagnóstico , Biomarcadores/sangue , Europa (Continente) , Feminino , Humanos , Incidência , Recém-Nascido , Masculino , Receptores de Antígenos de Linfócitos T/sangue , Imunodeficiência Combinada Severa/sangue , Imunodeficiência Combinada Severa/epidemiologia , Espanha/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...